1. Dual CPU single chip intelligent control technology, Microcomputer control, humanized design
2. Output high quality pure sine wave AC power,With strong load capacity, wide application range.
3. With perfect protection function, greatly improve reliability.
4. Adopt CPU centralized control and SMT technology
5. Stable operation, low distortion, no noise, no pollution, strong resistance to load impact, simple operation, long life, Panel menu LCD/LED display working status.
6. Three-stage charging function with battery type selection (optional)
7. Battery overvoltage, undervoltage protection
8. State grid automatic conversion (Optional)
9. It can automatically resume working after the undervoltage or over voltage change to normal
10. High conversion efficiency, high instantaneous power and low load loss.
11. It can achieve the connection of generator and external battery.
Diagram:
Off Grid Inverter Single phase 500w-4kw Technical Parameters:
Mode | XYH-500 | XYH-800 | XYH-1000 | XYH-1500 | XYH-2000 | XYH-3000 | XYH-4000 |
Rated power | 500w | 800w | 1000w | `1500w | 2000w | 3000w | 4000w |
Max. discharge current | 54A | 87A | 109A | 81.7A | 109A | 81.6A | 109A |
Input Battery Voltage | 12V | 12V | 12V | 24V | 24V | 48V | 48V |
Input grid AC voltage | 220/230/240Vac 50/60hz | ||||||
Output AC voltage | Single-phase 220/230/240%Vac | ||||||
Output current | 2.3A | 3.6A | 4.5A | 6.8A | 9A | 13.6A | 18A |
Output frequency | 50/60hz | ||||||
Size(W*L*H)mm | 420*220*295 | 445*245*190 | 445*245*190 | 300*450*585 | 300*450*585 | 300*450*595 | 350*600*650 |
Weight(Kg) | 15 | 16 | 19 | 40 | 46 | 54 | 76 |
General data | |||||||
Conversion time | 20ms~1s | ||||||
Nominal voltage | ±1%(Steady state load),±3%(Load fluctuation) | ||||||
Output waveform | Pure sine wave | ||||||
Current peak ratio | 3:1 MAX | ||||||
THD | Linear load < 3%; nonlinear load < 5% | ||||||
Standby power | <20W | ||||||
Overload capacity | >120%10s; >150%:5ms | ||||||
Protective function | <±5% | ||||||
Inversion efficiency | >90% | ||||||
Balance load voltage | <±1%;<±5%(Unbalanced load voltage) | ||||||
Protect function | Undervoltage protection of battery,state grid over voltage and undervoltage,inverter overload.overvoltage,over temperature,short circuit,automatic recovery after over voltage and undervoltage changing to normal. | ||||||
communication interface | RS232,(485、Remote Control,Options) | ||||||
Operating temperature | -10~60℃ | ||||||
Relative humidity (non condensing) | 30%~90% | ||||||
Operating altitude(maximum) | <1000Meters(every increased 1000Meters decrease power1%,highest5000Meters) | ||||||
cooling method | Forced air cooling | ||||||
Noise | ≤55dB(Depending on load and temperature)Distance to machine1M | ||||||
Easy maintenance | The front / upper / left and right sides can be opened. |
Off Grid Inverter Single phase 5kw-25kw Technical Parameters:
Mode | XYH-5000 | XYH-6000 | XYH-8000 | XYH-10000 | XYH-12000 | XYH-15000 | XYH-20000 |
Rated power | 5kw | 6kw | 8kw | `10kw | 12kw | 15kw | 20kw |
Max. discharge current | 136A | 81.7A | 109A | 109A | 81.7A | 102A | 109A |
Input Battery Voltage | 48V | 96V | 96V | 120V | 192V | 192V | 240V |
Input grid AC voltage | 220/230/240Vac 50/60hz | ||||||
Output AC voltage | Single-phase 220/230/240%Vac | ||||||
Output current | 23A | 27A | 36A | 45A | 54.5A | 68A | 91A |
Output frequency | 50/60hz | ||||||
Size(W*L*H)mm | 350*600*650 | 350*600*650 | 400*600*740 | 400*600*740 | 400*600*840 | 400*600*840 | 400*600*840 |
Weight(Kg) | 77 | 83 | 90 | 115 | 118 | 122 | 150 |
General data | |||||||
Conversion time | 20ms~1s | ||||||
Nominal voltage | ±1%(Steady state load),±3%(Load fluctuation) | ||||||
Output waveform | Pure sine wave | ||||||
Current peak ratio | 3:1 MAX | ||||||
THD | Linear load < 3%; nonlinear load < 5% | ||||||
Standby power | <20W | ||||||
Overload capacity | >120%10s; >150%:5ms | ||||||
Protective function | <±5% | ||||||
Inversion efficiency | >90% | ||||||
Balance load voltage | <±1%;<±5%(Unbalanced load voltage) | ||||||
Protect function | Undervoltage protection of battery,state grid over voltage and undervoltage,inverter overload.overvoltage,over temperature,short circuit,automatic recovery after over voltage and undervoltage changing to normal. | ||||||
communication interface | RS232,(485、Remote Control,Options) | ||||||
Operating temperature | -10~60℃ | ||||||
Relative humidity (non condensing) | 30%~90% | ||||||
Operating altitude(maximum) | <1000Meters(every increased 1000Meters decrease power1%,highest5000Meters) | ||||||
cooling method | Forced air cooling | ||||||
Noise | ≤55dB(Depending on load and temperature)Distance to machine1M | ||||||
Easy maintenance | The front / upper / left and right sides can be opened. |
Subscribe to our newsletter and be the first to know
about new productlaunches.
Add: No.220 Huayuan Road Jinan,China
Email:skyxo@126.com
Mobile/wechat/whatsapp:+86-186 5311 9810
Tel:+86-531-58539156
Copyright © Jinan Xinyuhua Energy Technology Co., Ltd. All Rights Reserved. Powered By HiCheng